Eris1D
Gamma and X-Rays radiation, and Alpha, Beta, Gamma contamination monitor
DISCONTINUED!
The new model ERiS2-D
replaces the Eris1D monitor.
The Eris1D is a handheld, compact and lightweight radiation monitor for detecting and measuring
two different types of measures: Gamma and X-Rays dose rate (µSv/h), and alpha, beta and gamma
radioactive contamination (cps).
The Eris1D has a Geiger-Müller detector with an open mica window for detecting the alpha, beta and gamma
contamination. The measure of contamination rate (cps) is performed placing the energy filter so that the
window of the detector is completely open. The measure of equivalent dose rate (µSv/h) is performed
placing the energy filter so that the window of the detector is completely covered. The way to switch
the type of measure is very easy: simply turning the energy filter, covering or not the window. A sensor
detects the filter position and sets automatically the measuring type on the display.
The monitor is ready to use as soon as it is turned on and the surfing on the menu is very intuitive
and user-friendly. The language of texts and messages are all in English. Its sophisticated firmware
calculates the average value of the detected events in last seconds, correcting the dead time of
the detector. This reading is very stable, but it is automatically updated when the radiation field
varies more than three times the standard deviation of the previous reading. This makes the monitor
has a fast response time and steady readings.
Both the dose rate in µSv/h and contamination rate in cps have two modes for displaying values: the
Rate mode in which the average value is updated each second, and the Hold mode in which the maximum
value reached is frozen on the display. Besides they have independent alarm threshold values, which
can be set by the user and stored in the non-volatile memory. In case a reading value is above its
alarm threshold value, an alarm message will be displayed. The monitor also has self-check routines
and displays a warning message if the battery level is low, if the detector fails or if the reading overflows.
After its manufacturing, the Eris1D is tested, adjusted and calibrated. The monitor is supplied with
a transport case with strap, with the user’s manual (in English) and certificates
with the results of the measures in equivalent dose rate H*(10) (related to Cs-137) and the results
of the calibration factors for some reference isotopes (ISO7503-1).
Type of measure | - With filter: Gamma y Rayos-X, H*(10), en Sv/h. - Withoul filter: Alfa, Beta, Gamma, en cps. |
Detector | Geiger-Müller, mica window of 7 cm² (with protection grill, 80% of transparency) |
Measuring modes | - Rate (dose or cps) - Maximum rate (dose or cps) |
Indication range | - In radiation: 0.01 µSv/h - 3 mSv/h - In contamination: 0.00 cps - 10 Kcps |
Optimun measuring range | 0.1 µSv/h - 3 mSv/h |
Gamma sensibility | aprox. 3 cps/µSv/h (related to Cs137) |
Accuracy | ±15% max., in measuring range |
Energy range | In radiation (with filter): 30 KeV to 2.5 MeV |
Energy dependence | In radiation (with filter): ±20% (relativo a Cs137) |
Typical 2pi efficiencies (4 mm. from the source) | In contaminación (without the filter): - Sr90+Y90 (β) ~ 38% - Cl36 (β) ~ 37% - C14 (β) ~ 10% |
Response time | Automatic, minimum 1 s. According to 3-Sigma criteria it updates the mesurement if the detected value in last second has a deviation above three times the standard deviation of average value |
Display | LCD 12x2 |
LED | - Frequency of events indicator - Alarm indicator |
Audio | Controlled by keyboard |
Keyboard | Four membrane pushbuttons: ON/OFF, MENU, AUDIO, RESET. |
Power | Alkaline 9 volts battery. More than 80 hours of continuous operation (with a rate <1 µSv/h) |
Dimensions | 11.7 x 7.2 x 3.0 cm |
Weight | 220 g. (with battery) |
Temperature range | -10ºC to +50ºC |
Humidity range | max. 90% RH (non condensed). |
![]() |
ERIS1D - Gamma and X-Rays radiation, and alpha, beta, gamma contamination monitor. Ref: LAM038V02 It is supplied with the following elements:
|
![]() |
Transport case for Eris1. Ref: LAM024V03
with strap. |
This table shows a comparison between Eris1D and other models of Eris1 family.
ERIS1R![]() |
ERIS1C![]() ![]() |
ERIS1D![]() ![]() |
|
Gamma and X-Rays H*(10) measurement | ✔ | ✔ | |
Alpha, Beta, Gamma contamination mesurement | ✔ | ✔ | |
µSv/h unit | ✔ | ✔ | |
CPS unit | ✔ | ✔ | |
Bq/cm² unit | ✔ | ||
Isotope library (calibration coefficients) | ✔ | ||
Rate measurement mode | ✔ | ✔ | ✔ |
Accumulated dose mode | ✔ | ||
Maximum rate mode (Hold) | ✔ | ✔ | ✔ |
Adjustable alarm threshold in µSv/h | ✔ | ✔ | |
Adjustable alarm threshold in cps | ✔ | ✔ | |
Adjustable alarm threshold in Bq/cm² | ✔ | ||
Self-testing with indication of alarms, detector fail, battery low level, and out of range | ✔ | ✔ | ✔ |
Counter/Timer with adjustable measuring time | ✔ |
Next table shows a comparison between Eris1D and instruments for radiation measurement.
ERiS2-R![]() |
ERiS2-M/G![]() |
ERiS2-D![]() |
RM1001-RD![]() |
RM1001B-RD![]() |
|
Gamma and X-Rays H*(10) measurement | ✔ | ✔ | ✔ | ✔ | ✔ |
Alpha, Beta, Gamma contamination measurement | with external sondes | ✔ | |||
Internal detector | ✔ | Optional | ✔ | Optional | Optional |
External sondes | Optional | Optional | Optional | ||
Multiprobe | ✔ | ||||
Hand-held | ✔ | ✔ | ✔ | ✔ | |
Stationary | Optional | Optional | ✔ | ||
Wall holder | Optional | Optional | ✔ | ||
Rechargeable battery | ✔ | ✔ | ✔ | ✔ | |
External power | ✔ | ✔ | |||
Data store | ✔ | ✔ | ✔ | Optional | |
Data Download/Register software | ✔ | ✔ | ✔ | Optional |
ERiS2-M/G![]() |
ERiS2-D![]() |
RM1001-CT![]() |
RM1001B-CT![]() |
||
Gamma and X-Rays H*(10) measurement | Optional | ✔ | |||
Alpha, Beta, Gamma contamination measurement | with external sondes | ✔ | ✔ | ✔ | |
Built-in contamination detector | ✔ | ||||
External contamination sondes | Several models | Several models | Several models | ||
Multiprobe | ✔ | ||||
Hand-held | ✔ | ✔ | ✔ | ||
Stationary | Optional | Optional | ✔ | ||
Wall holder | Optional | Optional | ✔ | ||
Rechargeable battery | ✔ | ✔ | ✔ | ||
External power | ✔ | ✔ | |||
Data store | Optional | ✔ | Optional | ||
Data Download/Register software | Optional | ✔ | Optional |