Gamma and X-Rays radiation, and Alpha, Beta, Gamma contamination monitor

  • Two types of measure: Gamma and X-Rays dose rate(µSv/h), and Alpha, Beta, Gamma contamination rate (cps)
  • Geiger-Müller detector with 7 cm² thin window
  • Small, compact and light-weight
  • Two indication modes: Rate and maximum rate (Hold)
  • Two alarm thresholds, in µSv/h and cps
  • Self-test with indication of alarms, detector error, low battery, and out of range.


DISCONTINUED!

The new model ERiS2-D
replaces the Eris1D monitor.

The Eris1D is a handheld, compact and lightweight radiation monitor for detecting and measuring two different types of measures: Gamma and X-Rays dose rate (µSv/h), and alpha, beta and gamma radioactive contamination (cps).

The Eris1D has a Geiger-Müller detector with an open mica window for detecting the alpha, beta and gamma contamination. The measure of contamination rate (cps) is performed placing the filter so that the window of the detector is completely open. The measure of equivalent dose rate (µSv/h) is performed placing the filter so that the window of the detector is completely covered. The way to switch the type of measure is very easy: simply turning the filter, covering or not the window. A sensor detects the filter position and sets automatically the measuring type on the display.

The monitor is ready to use as soon as it is turned on and the surfing on the menu is very intuitive and user-friendly. The language of texts and messages are all in English. Its sophisticated firmware calculates the average value of the detected events in last seconds, correcting the dead time of the detector. This reading is very stable, but it is automatically updated when the radiation field varies more than three times the standard deviation of the previous reading. This makes the monitor has a fast response time and steady readings.

Both the dose rate in µSv/h and contamination rate in cps have two modes for displaying values: the Rate mode in which the average value is updated each second, and the Hold mode in which the maximum value reached is frozen on the display. Besides they have independent alarm threshold values, which can be set by the user and stored in the non-volatile memory. In case a reading value is above its alarm threshold value, an alarm message will be displayed. The monitor also has self-check routines and displays a warning message if the battery level is low, if the detector fails or if the reading overflows.

After its manufacturing, the Eris1D is tested, adjusted and calibrated. The monitor is supplied with a transport case with strap, with the user’s manual (in English) and certificates with the results of the measures in equivalent dose rate H*(10) (related to Cs-137) and the results of the calibration factors for some reference isotopes (ISO7503-1).

Type of measure - With filter: Gamma y Rayos-X, H*(10), en Sv/h.
- Withoul filter: Alfa, Beta, Gamma, en cps.
Detector Geiger-Müller, mica window of 7 cm² (with protection grill, 80% of transparency)
Measuring modes - Rate (dose or cps)
- Maximum rate (dose or cps)
Indication range - In radiation: 0.01 µSv/h - 3 mSv/h
- In contamination: 0.00 cps - 10 Kcps
Optimun measuring range 0.1 µSv/h - 3 mSv/h
Gamma sensibility aprox. 3 cps/µSv/h (related to Cs137)
Accuracy ±15% max., in measuring range
Energy range In radiation (with filter): 30 KeV to 2.5 MeV
Energy dependence In radiation (with filter): max ±25% for E>200KeV and E<2.5MeV (related to Cs137)
High dependence for E<200KeV, calibration required
Typical 2pi efficiencies
(4 mm. from the source)
In contaminación (without the filter):
- Sr90+Y90 (β) ~ 38%
- Cl36 (β) ~ 37%
- C14 (β) ~ 10%
Response time Automatic, minimum 1 s. According to 3-Sigma criteria it updates the mesurement if the detected value in last second has a deviation above three times the standard deviation of average value
Display LCD 12x2
LED - Frequency of events indicator
- Alarm indicator
Audio Controlled by keyboard
Keyboard Four membrane pushbuttons: ON/OFF, MENU, AUDIO, RESET.
Power Alkaline 9 volts battery. More than 80 hours of continuous operation (with a rate <1 µSv/h)
Dimensions 11.7 x 7.2 x 3.0 cm
Weight 220 g. (with battery)
Temperature range -10ºC to +50ºC
Humidity range max. 90% RH (non condensed).

ERIS1D - Gamma and X-Rays radiation, and alpha, beta, gamma contamination monitor.

Ref: LAM038V02

It is supplied with the following elements:

  • Eris1D monitor
  • Transport case with strap.
  • 9V battery
  • User's manual in english
  • Calibration certificate of LAMSE


ACCESORIOS:

Transport case for Eris1.

Ref: LAM024V03

with strap.
In new orders, this transport case is already included with any Eris1

This table shows a comparison between Eris1D and other models of Eris1 family.
ERIS1R
ERIS1C
ERIS1D
Gamma and X-Rays H*(10) measurement
Alpha, Beta, Gamma contamination mesurement
µSv/h unit
CPS unit
Bq/cm² unit
Isotope library (calibration coefficients)
Rate measurement mode
Accumulated dose mode
Maximum rate mode (Hold)
Adjustable alarm threshold in µSv/h
Adjustable alarm threshold in cps
Adjustable alarm threshold in Bq/cm²
Self-testing with indication of alarms, detector fail, battery low level, and out of range
Counter/Timer with adjustable measuring time


Next table shows a comparison between Eris1D and instruments for radiation measurement.
ERiS2-R
ERiS2-M/G
ERiS2-D
RM1001-RD
RM1001B-RD
Gamma and X-Rays H*(10) measurement
Alpha, Beta, Gamma contamination measurement with external sondes
Internal detector Optional Optional Optional
External sondes Optional Optional Optional
Multiprobe
Hand-held
Stationary Optional Optional
Wall holder Optional Optional
Rechargeable battery
External power
Data store Optional
Data Download/Register software Optional

Next table shows a comparison between Eris1D and instruments for contamination measurement.
ERiS2-M/G
ERiS2-D
RM1001-CT
RM1001B-CT
Gamma and X-Rays H*(10) measurement Optional
Alpha, Beta, Gamma contamination measurement with external sondes
Built-in contamination detector
External contamination sondes Several models Several models Several models
Multiprobe
Hand-held
Stationary Optional Optional
Wall holder Optional Optional
Rechargeable battery
External power
Data store Optional Optional
Data Download/Register software Optional Optional

  • Firemen, police and emergency services
  • Hazardous goods transport
  • Research centers
  • Hospitals
  • Universities
  • Radiological protection
  • X-Rays systems
  • Industry with radioactive sources
  • etc...